Product Details:

  • Door Opening Size Adjustable; covers various door widths
  • Usage Automatic Door Protection
  • Noise Level Silent Operation
  • Type Infrared Door Sensor
  • Voltage 12-24 V DC
  • Material ABS / Polycarbonate Housing
  • Power Supply 12 V / 24 V DC
  • Click to View more
X

Elevator Door Detector Sensor Price and Quantity

  • 1 , , Piece
  • 4200 INR/Piece

Elevator Door Detector Sensor Specification

  • -20C to +65C
  • ABS / Polycarbonate Housing
  • Microcontroller Based
  • 12-24 V DC
  • Light Curtain / Photocell
  • Infrared Door Sensor
  • Photoelectric Obstacle Detection
  • Silent Operation
  • Adjustable; covers various door widths
  • Automatic Door Protection
  • 12 V / 24 V DC

Elevator Door Detector Sensor Trade Information

  • 5 , , Piece Per Day
  • 1-7 Days

Product Description

Elevator door detector sensors are a basic part of elevator frameworks that guarantee traveler security and legitimate activity. These sensors are intended to identify articles or checks in the doorway region of an elevator, keeping the doors from shutting when there is a deterrent. Elevator door detector sensors ought to go through normal upkeep and testing to guarantee their legitimate working. Elevator support staff commonly incorporate sensor checks as a component of their standard examinations and upkeep methodology.


FAQs of Elevator Door Detector Sensor:

Q1: What is an elevator door detector sensor, and what is its essential capability?

A1: An elevator door detector sensor is a gadget introduced on or close to elevator doors. Its essential capability is to identify articles or blocks in the doorway region and keep the doors from shutting when such deterrents are available, guaranteeing traveler security.


Q2: What kinds of sensors are normally utilized in elevator door detectors?

A2: Normal kinds of sensors utilized in elevator door detectors incorporate infrared (IR) sensors, ultrasonic sensors, nearness sensors, and photocell sensors. Each type has its own strategy for identifying impediments.


Q3: How do elevator door detector sensors function?

A3: Elevator door detector sensors work by discharging signals (like light, sound, or electromagnetic fields) across the doorway. At the point when an impediment hinders or mirrors these signs, the sensor identifies it and conveys a message to the elevator control framework to forestall door conclusion.


Q4: For what reason are elevator door detector sensors significant for security?

A4: Elevator door detector sensors are pivotal for traveler security since they keep the doors from shutting on individuals, articles, or deterrents. This keeps away from mishaps and wounds in and around elevators.


Q5: Are elevator door detector sensors customizable?

A5: Numerous elevator door detector sensors are customizable regarding awareness. This permits them to be adjusted to the particular elevator's design and ecological circumstances.


Q6: What happens when an elevator door detector sensor identifies a hindrance?

A6: When a block is distinguished, the sensor conveys a message to the elevator control framework, which answers by keeping the doors open or resuming them on the off chance that they had begun shutting. This guarantees that the doors stay open until the area is clear.


Q7: Are elevator door detector sensors subject to administrative norms?

A7: Indeed, elevator wellbeing, including the usefulness and norms for door detector sensors, is much of the time subject to severe administrative necessities and guidelines in numerous nations. These guidelines are set up to guarantee traveler security.


Q8: Might elevator door detector sensors at any point be coordinated with other wellbeing highlights in elevators?

A8: Indeed, elevator door detector sensors are regularly coordinated into the general elevator control framework, working related to other wellbeing highlights, for example, door returning components, crisis stop fastens, and interlocks.

Technical Details



Customizable Beam Array

The Elevator Door Detector Sensor provides options of 32, 40, or 154 beams, offering adaptable protection for a variety of door sizes and types. Its customizable design ensures accurate obstacle detection, reducing the risk of accidents and enhancing passenger safety in multiple elevator configurations.


Robust Performance and Durability

Built with an IP54 rating, this detector is resistant to dust and water splashes, making it ideal for high-traffic environments. It operates effectively in temperatures from -20C to +65C and under humidity levels below 95% RH, ensuring reliable service regardless of climate.


Simple Installation and Versatile Output

The sensor can be flush or surface mounted and supports both relay and transistor outputs (NPN/PNP), making integration with different elevator control systems seamless. With a standard 2-meter extendable cable, installation and maintenance are straightforward for various panel thicknesses.

FAQ's of Elevator Door Detector Sensor:


Q: How is the Elevator Door Detector Sensor installed?

A: The sensor supports both flush and surface mounting, catering to various elevator door configurations. A standard 2-meter cable is included and can be extended for wider doors, and it is suitable for panel thicknesses ranging from 9 to 15 mm.

Q: What types of elevator doors are compatible with this detector?

A: This detector is designed for universal applicability and covers both passenger and freight elevator doors. The adjustable door opening size ensures coverage of a wide range of door widths.

Q: When should the sensor be replaced or maintained?

A: With a lifetime of over 5 million cycles and robust materials, the sensor requires minimal maintenance. However, periodic checks every year are recommended to ensure the light curtain and LED status indicators are functioning correctly.

Q: Where can the sensor be used with respect to environmental conditions?

A: The detector features an IP54 rating and operates reliably between -20C and +65C, with light immunity up to 100,000 Lux and humidity tolerance below 95% RH non-condensing, making it suitable for various indoor environments.

Q: What is the process of integrating this door detector with existing elevator controls?

A: Integration is straightforward thanks to selectable output types (Relay, NPN, and PNP), enabling compatibility with most microcontroller-based elevator control systems and safety circuits.

Q: How does the light curtain mechanism enhance elevator safety?

A: The infrared light curtain creates a dense network of beams-customizable to 32, 40, or 154-across the elevator doorway. The system instantly detects any obstruction, triggering the elevator doors to stop or reverse safely, thus preventing accidents.

Q: What are the primary benefits of using this elevator door detector sensor?

A: Key benefits include enhanced passenger safety through instant obstacle detection, silent operation, adaptability to door and panel sizes, immunity to ambient light, simple installation, and long-term durability exceeding 5 million cycles.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top